Recommended Hardware: Application Nodes and Power Controllers

Intended for use with Cassatt Active Response Standard Edition, Premium Edition and Data Center Edition V5.1.

Although Cassatt Active Response does not impose many restrictions on the hardware you use, Cassatt does have experience with and recommends several vendors. The following sections list hardware by vendor that Cassatt recommends for use as application nodes with Cassatt Active Response. Also, to anticipate the ways you can utilize application nodes in a Cassatt Active Response environment, see Understanding How Hardware Gets Under Cassatt Management.

Dell

The following table shows versions of Dell's Remote Access Controller (RAC) cards supported by Cassatt Active Response: ERA, DRAC III/XT, and DRAC 4/I. You can use server models with these RAC versions as application nodes, such as 750, 2650, 1750, 1950, and 2950. For a comprehensive list of Dell hardware with accompanying RAC types, see Dell's Remote Access Service Availability.

Power controller and firmware version

Dell Remote Access Card (DRAC) III/XT 3.30 (Build 4.19)

Embedded Remote Access (ERA) 3.14 (Build 08.19)

Embedded Remote Access/Option (ERA/0) 3.35 (build 11.25)

Dell Remote Access Controller (DRAC 5) 1.21

top

HP

The following table shows versions of HP's Integrated Lights Out Management (iLO) supported by Cassatt. You can use server models with these iLO versions as application nodes, such as DL360 G3, DL360 G4, DL360 G4P, DL360 G5, DL 380 G4, and DL 385.

Power controller and firmware version

Integrated Lights Out Management (iLO) 1.75

Integrated Lights Out Management (iLO) 1.75

Integrated Lights Out Management (iLO) 1.72

Integrated Lights Out Management (iLO2) 1.29

Integrated Lights Out Management (iLO) 1.82

Integrated Lights Out Management (iLO) 1.82

top

IBM

Cassatt supports BCMM 1.21K (BRET86L revision 16) for use with application nodes. Applicable hardware includes the eServer Bladecenter chassis (8677) and Blade models such as HS20-8678, HS20-8832, and HS20-8843.

top

Sun

Cassatt supports Sun ALOM and ILOM for application nodes. You can use server models with these power controllers as application nodes, such as Sun Fire T2000, Sun Fire v20z, and Sun Fire X4100.

top

External power controllers

Application nodes that do not have an integrated power controller that's supported by Cassatt Active Response can still take advantage of Cassatt Active Response node management by using an external power controller. After you configure and add an external power controller to Cassatt Active Response, Cassatt Active Response can use it to power nodes on and off. Cassatt supports the controllers in the next table.

Vendor

Model

APC

APC7900, APC7901 or other APC switched-rack series that supports SNMP access with a minimum firmware version of 3.3

Baytech

Baytech RPC3DE or other Baytech RPC series that supports SNMP access with a minimum network controller board firmware version of 2.11.02 or higher.

NOTE:

Cyber Switching Dualcom

D1630ViBR or other series that supports SNMP

Server Technology Server Technology Sentry Switched CDU CW-24V

Western Telematic Inc. (WTI)

Internet Power Switch (IPS) 800 or other IPS series that supports telnet access

Servers must meet certain criteria to serve as Cassatt application nodes when powered by external power controllers; see External Power Controllers: Qualifying Node and Other Best Practices.