Dell: Nodes with Integrated Power Controllers
Intended for use with Cassatt Active Response Premium Edition and Data Center Edition V5.1.
This article describes how to configure Dell application nodes with ERA, DRAC4 and DRAC5 integrated power controllers for utility computing. Complete this step before adding nodes to the Cassatt Active Response Controller for Cassatt management.
Step 1: Configure the application node for PXE and network booting
Follow these steps to configure the application nodes for Cassatt Active Response management.
- Connect a console, keyboard, and mouse to the application node.
- If the first NIC in the application node is not going to be managed by Cassatt Active Response, make sure it is either unplugged, or plugged into its appropriate network.
- Power on the application node using the power button on the front panel.
- Press F2 to access the BIOS.
- Set the boot sequence so "Network" comes before the "hard drive" in the list; the remaining order can be set per your site requirements.
"Network" must come before the “Hard drive”option in the boot order or the node will not boot. If you place “Network” first in the boot order, you gain a small optimization in speed for node discovery and in moving nodes to the free pool. If you are operating in a test environment or you expect to need frequent administrative access to the application nodes, you can set the order to Floppy, CD-ROM, Network.
-
Select the Integrated Devices option and set as follows.
Setting |
Enter |
| Integrated devices |
Embedded NIC 1.................Enable with PXE
Embedded NIC 2.................Enable with PXE |
- Enable console redirection as follows.
Power controller |
Enter |
| ERA |
Redirection.....................Off
Remote Terminal Type............VT100/VT220
Redirection after Boot..........Enabled |
| DRAC 4 |
Redirection.....................Serial Port 1
Failsafe Baud Rate..............57600
Remote Terminal Type............VT100/VT220
Redirection after Boot..........Enabled |
| DRAC 5 |
Serial Communications...........On with Console Redirection via COM2
External Serial Connector.......Remote Access Device
Failsafe Baud Rate..............57600
Remote Terminal Type............VT100/VT220
Redirection after Boot..........Enabled |
- Set the remaining BIOS parameters as required by your site.
- Save the changes and exit.
top
Step 2: Configure the power controller for DHCP
Follow these steps to configure the application node power controller for DHCP.
- Boot the node and access the Dell remote access configuration utility.
- Enable DHCP using the following guidelines.
| Power controller |
Enter |
| ERA and DRAC 4 |
NIC TCP/IP Configuration Options......Use DHCP is: Enabled
Ethernet Configuration Options........NIC is: Enabled |
| DRAC 5 |
LAN Parameters........................IP Address Source..DHCP
Advanced LAN Parameters...............NIC................Enabled |
- Save changes and exit.
This may take a few minutes to complete.
top